196 Install and configure IP Trunk 3.01 (and later) node
For more detailed cabling information and procedures for replacing the
NT8D81BA with the NT8D81AA, see Appendix "Patches and advisements"
(page 429).
Install NTMF94EA and NTCW84KA cables
The Media Card 32-port and ITG-Pentium 24-port trunk card supports a
one-cable solution for access to the TLAN network interface, ELAN network
interface, and serial ports. The ELAN network interface supports 10BaseT
operation and the TLAN network interface supports 10/100BaseT operation.
If using a 100BaseT operation on the TLAN network interface, install a
NTCW84JA 50-pin I/O panel filter connector block to replace the standard
I/O connectors provided.
Cables that are provided for the ELAN and TLAN network interface functions
include the following:
the NTMF94EA ELAN, TLAN, and RS-232-port cable (for non-DCHIP
cards)
the NTCW84KA ELAN, TLAN, RS-232 and DCH Ports cable (for DCHIP
cards)
Install the NTCW84KA cable (for DCHIP cards)
Follow the steps in Procedure 9 "Installing the NTCW84KA cable" (page
196) to connect the NTCW84KA cable for DCHIP cards.
Procedure 9
Installing the NTCW84KA cable
Step Action
1
Connect the NTCW84KA cable see to the I/O panel connector (see
Figure 36 "NTCW84KA ELAN, TLAN, DCH, and serial cable" (page
197)).
Make sure to connect to the I/O panel connector that corresponds to
the left slot number of the DCHIP card.
2
Secure the mounting screw provided on the top of the Shielded
25-Pair Amphenol Connector to the I/O Panel filter connector in
order to tie the shield of the LAN cable to the frame ground for EMC
compliance.
—End—