Server features 13
Clearance
front: 2 inches (50.8 mm)
rear: 3.6 inches (92 mm)
side: 1 inch (25 mm)
Weight of fully loaded system with:
SCSI hard drive
MPB96 board
DVD/CD/CDRW drive
approximately 10 kg (23 lbs)
Environmental specifications
Environmental condition
Specification
Operating temperature
+5
C to +35 C (41 Fto95
F)
Maximum rate of change must not
exceed 10
C (50 F) per hour.
Non-operating (storage) temperature
-40
C to +70 C (-40 F to +158 F)
Non-operating humidity
95% @ 23-40
C
Altitude <6000 ft. (1829 m)
Electrostatic discharge <= 15 kV
Acoustic noise < 55 dBA
Operating shock No errors with a half sine wave shock
of 2G (with 1 millisecond duration)
Handling drop 2g 11 mS
18" free-fall when packaged
Front panel features
The following diagram shows the front view of the server chassis with the
bezel cover in place. When the bezel cover is removed, Drive Bay 1 is
accessible.