Web OS 10.0 Application Guide
334
Chapter 13: Firewall Load Balancing
212777-A, February 2002
Configure Connectivity for the Primary Clean-Side Web Switch
1. Configure VLANs on the primary clean-side Web switch.
Two VLANs are required. VLAN 3 includes the firewall port and interswitch connection port.
VLAN 4 includes the port that attaches to the real servers.
2. Configure IP interfaces on the primary clean-side Web switch.
3. Turn STP off for the primary clean-side Web switch.
>> # /cfg/vlan 3
>> # add 3
>> # add 9
>> # ena
>> # ../vlan 4
>> # add 4
>> # ena
>> # /cfg/ip/if 1
>> # mask 255.255.255.0
>> # addr 10.10.4.10
>> # vlan 4
>> # ena
>> # ../if 2
>> # mask 255.255.255.0
>> # addr 10.10.3.1
>> # vlan 3
>> # ena
>> # ../if 3
>> # mask 255.255.255.255
>> # addr 10.10.3.2
>> # vlan 3
>> # ena
>> # /cfg/stp/off