286 2.0 Mb ISL implementation
Figure 90
ISL in dedicated mode using dialup modem
ISL hardware installation
Shared mode
The hardware installation is identical to the PRI installation, with the addition
of analogue or digital TIE trunks (or both).
Dedicated mode
The NTAK02 connects to the modem through the NTAK19BA 4-port cable.
Only ports 1 and 3 are available for use as DCHIs.
Procedure 42
Installing the NTAK02
Step Action
1 Set option switches/jumpers on the DCHI card, as shown in Table
104 "NTAK02 switch settings" (page 287) and Table 105 "NTAK02
jumper settings" (page 287), for mode of operation that is, RS232 or
RS422 and DTE or DCE.
2
Install the NTAK02 in any spare slot 1-9 of the Main Cabinet or slots
11-14 of the Media Gateway.
3
Install the NTAK19BA four port cable on the 50-pin Amphenol
connector associated with the slot holding the NTAK02.
Nortel Communication Server 1000
ISDN Primary Rate Interface Installation and Commissioning
NN43001-301 02.03 Standard
Release 5.5 7 December 2007