316 Survivability
LD 15: Customer Data Block
Prompt Response Description
REQ: CHG Change existing data block
TYPE: INT Change Intercept Treatment
CUST Customer number
0-31
Range for Small System, CS 1000S system, Media
Gateway 1000B, and Media Gateway 1000T
...
MBNR MAIL MAIL MAIL MAIL
MLDN
xxxx
Mail DN
The following is a sample printout of the Customer Data Block (CDB). Use
LD 21 to print the CDB.
>ld 21
REQ: prt
TYPE: int
TYPE INT_DATA
CUST 0
TYPE INT_DATA
CUST 00
ACCD OVF OVF OVF ATN
CTVN OVF OVF OVF ATN
MBNR MAIL MAIL MAIL MAIL
MLDN 3001
CTRC OVF NAP OVF NAP
CLDN NAP OVF NAP NAP
NINV OVF OVF OVF ATN
NITR OVF OVF OVF ATN
NRES OVF OVF OVF ATN
NBLK OVF OVF OVF ATN
MVFO OVF OVF OVF ATN
MFVN OVF OVF OVF ATN
MFCG OVF OVF OVF ATN
LCKT BSY BSY BSY BSY
RCLE ATN OVF ATN ATN
CONG OVF
DLT OVF
LLT OVF
DNDT BSY