110 Option settings
Unit 0 jumper (Location E27)
Unit 1 jumper (Location E11)
Unit 2 jumper (Location D29)
Unit 3 jumper (Location D9)
Jumper:
Unit 0
Jumper
Unit 1
Jumper
Unit 2
Jumper
Unit 3
Jumper
600
3
/4 resistive impedance Pin 1 to 2 Pin 1 to 2 Pin 1 to 2 Pin 1 to 2
3-component complex impedance Pin 2 to 3 Pin 2 to 3 Pin 2 to 3 Pin 2 to 3
QPC471 Clock Controller card
Table 50 "QPC471 vintage H" (page 110) lists option settings for the
QPC471 Clock Controller card.
Table 50
QPC471 vintage H
SW1 SW2 SW4
System 1 2 3 4 1 2 3 4 1 2 3 4
61C
on on on on
off off off off off
on
**
81
off off off off off off off off off
on
**
81C
on
off off off off off off off **
on
**
81C with Fiber Network
on
off off off off off off off **
on
**
*Cable length between the J3
faceplate connectors:
0–4.3 m (0–14 ft) off off
4.6–6.1 m (15–20 ft) off
on
6.4–10.1 m (21–33 ft)
on
off
10.4–15.2 m (34–50 ft)
on on
*If there is only one Clock Controller card in the system, set to OFF. If there are two Clock Controller
cards, determine the total cable length between the J3 connectors (no single cable can exceed 25
ft.) and set these two switch positions for this cable length, as shown above. The maximum total
(combined) length is 50 ft. Set the switches on both cards to the same settings.
**Set to ON for clock controller 0. Set to OFF for clock controller 1.
Note: FNF based-systems the total clock path length is equal to the length of the NTRC49 cable
used to connect between the two clock controller cards.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 01.04 Standard
Release 5.0 23 May 2008
Copyright © 2003-2008, Nortel Networks
.