Nortel-networks M3310 Manual do Utilizador Página 166

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 165
166 Digital Telephone IP Adapter Installation and Administration Guide
Administration Standard 2.1
Note: Do not ignore error messages in Save to Flash process. If Save to
Flash fails, retry uploading and saving to Flash. If the problem persists,
check the file being uploaded and report the problem to Nortel.
9 From the Upload Configuration dialog box, click on the Save to Flash
button.
Result: The FLASH CONFIG dialog box displays, similar to the following:
10 Click on the Yes button.
Result: The following message displays in the status bar at the bottom of
the screen:
Saving to Flash in Progress
When the save is finished, the following message displays in the middle of
the Upload Configuration dialog box:
CONFIGURATION IS UPDATED INTO FLASH...
11 Click on the Close button.
12 Restart the RLC.
Note: For instructions, refer to “Restarting the system” on page 204.
IF the upload THEN
is successful,
the following message displays:
CONFIG UPLOAD SUCCESSFUL... USE
SAVECFG TO UPDATE FLASH.
fails,
the following message displays in the middle of the
Upload Configuration dialog box:
CONFIG UPLOAD FAILED
For further instructions, refer to Chapter 8,
“Troubleshooting”.
Vista de página 165
1 2 ... 161 162 163 164 165 166 167 168 169 170 171 ... 263 264

Comentários a estes Manuais

Sem comentários